2460008

ten year planning permission with a 40-year operational life (from the date of commissioning of the development). (ii) Construction of 4 No. wind turbines with an overall ground to blade tip height ranging from 149.85m to 150m inclusive. The wind turbines will have a rotor diameter ranging from 115.7m to 117m inclusive and a hub height ranging from 91.5m to 92m inclusive. (iii) Construction of permanent turbine hardstands and turbine foundations. (iv) Construction of a bottomless bridge culvert across a minor stream on site (EPA River Segment Code: 26_4053). (v) Construction of one temporary construction compound with associated temporary site offices, parking areas and security fencing. (vi) Installation of one (40-year life cycle) meteorological mast with a height of 50m and a 4m lightning pole on top. (vii) Construction of new internal site access tracks and upgrade of a section of existing internal Site track, to include all associated drainage. (viii) Improvement of existing site entrance with access via the L4282. (ix) Development of an internal site drainage network and sediment control systems. (x) Construction of 1 no. permanent 20kV electrical substation. (xi) All associated underground electrical and communications cabling connecting the wind turbines to the wind farm substation. (xii) All works associated with the connection of the wind farm to the national electricity grid, which will be via 20kV underground and partially overhead cable connection approximately 6.4km in length to the existing ESB Corderry 110kV Substation in the townlands of Letter, Greaghnadarragh, Stangaun, Corralustia, Turpaun, Gortnasillagh West, Lugmeeltan, Leckaun, Lisgavneen, Treannadullagh, Drumcashlagh and Corderry. (xiii) Ancillary forestry felling to facilitate construction of the development. (xiv) All associated site development works including berms, landscaping, and soil excavation. (xv) Installation of battery arrays located within container units (2 no. units) and associated electrical plant for grid stabilisation adjacent to the substation building. (xvi) Development of one on-site borrow pit.

Refused

Core Refusal Reason

The development was refused primarily due to the elevated risk of a major landslide event and subsequent environmental pollution, alongside concerns regarding the integrity of European protected sites and cumulative impacts on sensitive bird species.

Decision Maker's Conclusion

  • The applicant failed to demonstrate that the development would not result in a peat landslide, posing a serious danger of extensive pollution to local waterbodies and the wider environment.
  • Definitive scientific doubt exists that the proposal would not adversely affect the integrity of the Lough Gill SAC and Unshin River SAC European Sites, particularly in relation to the foraging range of otters.
  • The Planning Authority is not satisfied that the cumulative environmental assessment can reasonably exclude the possibility of a significant impact on avifauna of conservation value in an ecologically sensitive area.

Cited Policies (CDP)

Section 2.2Section 4Section 5Section 9Section 10Section 11Section 11.13Section 12CA POL 1CA POL 2RE POL 1RE POL 2RE POL 3RE OBJ 1Section 12.6.2WE POL 1WE POL 2WE POL 3WE POL 4WE POL 5WE POL 6WE POL 7WE OBJ 1Section 13Section 13.20Section 13.20.4NH POL 1NH POL 2NH POL 3NH POL 4NH POL 5NH POL 6NH POL 7NH POL 8NH POL 10NH OBJ 1NH OBJ 2NH OBJ 3NH OBJ 4NH OBJ 5PEAT POL 1PEAT POL 2

Decision Document Summary

Letter Wind Farm Limited proposed a four-turbine wind energy development with a 6.4km grid connection in the townlands of Letter, Boleybaun, and others near Drumkeeran, Co. Leitrim. The Planning Authority refused permission based on the high risk of peat instability and landslides in an area with a significant history of such events, concluding that the applicant's Peat Stability Hazard Assessment was not sufficiently robust. Furthermore, the authority determined that the project could not guara...
SOURCE PDFOpen Original
Note: If code appears below, the council site is blocking the preview. Please open the original file.